Isıtma ve Soğutma Gün Dereceleri

Gösterim Şekli Aylık Değerlendirme Yıllık Değerlendirme


Merkez G/D Oca Şub Mar Nis May Haz Tem Ağu Eyl Eki Kas Ara Yıllık
BOYABAT

2024
HDD 455 294 273 1022
T≤15 °C 31 29 28 88
CDD 0
T>22 °C 0
BOYABAT

2023
HDD 379 388 280 158 67 67 198 372 1909
T≤15 °C 31 28 31 26 14 15 24 31 200
CDD 1 31 85 15 132
T>22 °C 2 18 30 8 58
BOYABAT

2022
HDD 505 349 412 102 50 54 159 265 1896
T≤15 °C 31 28 31 18 12 11 25 31 187
CDD 0 5 30 49 134 33 0 251
T>22 °C 1 4 17 24 31 11 1 89
BOYABAT

2021
HDD 421 351 356 161 15 4 17 95 268 387 2075
T≤15 °C 31 28 31 23 3 1 4 17 30 31 199
CDD 3 22 114 96 1 236
T>22 °C 4 12 29 26 1 72
BOYABAT

2020
HDD 439 386 229 177 49 7 285 394 1966
T≤15 °C 31 29 29 26 10 2 29 31 187
CDD 23 35 108 74 58 0 298
T>22 °C 8 16 31 27 24 1 107
BOYABAT

2019
HDD 454 325 313 140 36 8 23 262 413 1974
T≤15 °C 31 28 31 20 8 2 7 30 31 188
CDD 11 61 47 65 3 2 189
T>22 °C 7 27 22 25 5 1 87
BOYABAT

2018
HDD 419 298 227 51 10 20 54 255 402 1736
T≤15 °C 31 28 29 9 2 4 9 30 31 173
CDD 2 27 74 79 17 2 201
T>22 °C 5 14 29 25 6 1 80
BOYABAT

2017
HDD 530 401 265 167 30 140 326 428 2287
T≤15 °C 31 28 31 21 7 26 30 31 205
CDD 2 2 23 106 108 43 284
T>22 °C 1 2 12 29 24 17 85
BOYABAT

2016
HDD 493 299 261 68 51 3 18 117 343 542 2195
T≤15 °C 31 29 30 14 12 1 4 17 29 31 198
CDD 52 78 100 6 236
T>22 °C 16 28 26 8 78
BOYABAT

2015
HDD 515 346 301 202 40 87 283 510 2284
T≤15 °C 31 27 30 24 9 14 30 31 196
CDD 10 5 73 102 53 243
T>22 °C 8 4 26 27 25 90
BOYABAT

2014
HDD 443 317 247 99 24 4 79 291 392 1896
T≤15 °C 31 28 29 17 6 1 15 30 31 188
CDD 1 12 113 131 29 286
T>22 °C 2 8 30 29 13 82
BOYABAT

2013
HDD 438 299 267 115 144 269 579 2111
T≤15 °C 31 28 28 19 24 30 31 191
CDD 6 32 59 70 3 170
T>22 °C 4 10 29 29 2 74
BOYABAT

2012
HDD 523 501 393 73 19 213 415 2137
T≤15 °C 31 29 31 12 5 25 31 164
CDD 0 58 103 53 11 0 225
T>22 °C 1 21 26 25 12 1 86
BOYABAT

2011
HDD 466 376 316 219 48 140 406 453 2424
T≤15 °C 31 28 31 29 9 20 30 31 209
CDD 8 98 46 4 156
T>22 °C 7 28 24 7 66
BOYABAT

2010
HDD 443 283 287 142 26 126 236 374 1917
T≤15 °C 31 28 31 25 7 21 30 31 204
CDD 5 33 111 176 24 349
T>22 °C 3 14 30 30 15 92
BOYABAT

2009
HDD 521 344 343 171 62 9 25 297 390 2162
T≤15 °C 31 28 31 26 15 2 5 30 31 199
CDD 3 33 51 25 2 114
T>22 °C 3 15 20 14 4 56
BOYABAT

2008
HDD 629 482 222 103 73 4 85 261 476 2335
T≤15 °C 31 29 29 17 13 1 20 29 31 200
CDD 0 6 26 70 112 10 224
T>22 °C 1 3 13 26 30 13 86
BOYABAT

2007
HDD 470 407 306 246 18 66 338 460 2311
T≤15 °C 31 28 30 30 4 13 30 31 197
CDD 25 49 115 126 37 352
T>22 °C 12 19 26 30 8 95
BOYABAT

2006
HDD 558 449 272 120 81 88 359 532 2459
T≤15 °C 31 28 30 20 15 18 30 31 203
CDD 8 40 39 169 1 257
T>22 °C 3 17 23 31 1 75
BOYABAT

2005
HDD 415 371 354 148 45 164 323 452 2272
T≤15 °C 31 28 31 17 8 23 30 31 199
CDD 3 11 101 117 5 237
T>22 °C 2 7 30 30 5 74
BOYABAT

2004
HDD 494 413 300 154 41 17 79 311 475 2284
T≤15 °C 31 28 28 22 9 4 17 30 31 200
CDD 1 34 42 6 83
T>22 °C 2 17 23 7 49
BOYABAT

2003
HDD 366 412 408 161 3 7 86 326 466 2235
T≤15 °C 31 28 31 26 1 2 13 30 31 193
CDD 9 54 68 9 140
T>22 °C 11 27 29 3 70
BOYABAT

2002
HDD 660 388 247 157 27 84 301 536 2400
T≤15 °C 31 28 31 26 7 15 30 31 199
CDD 2 18 93 62 0 175
T>22 °C 2 12 31 26 2 73
BOYABAT

2001
HDD 419 342 204 101 42 118 297 473 1996
T≤15 °C 31 28 28 20 9 18 30 31 195
CDD 27 101 111 10 249
T>22 °C 14 27 30 12 83
BOYABAT

2000
HDD 551 437 360 83 51 4 15 134 289 445 2369
T≤15 °C 31 29 30 14 8 1 3 22 30 31 199
CDD 14 141 69 9 233
T>22 °C 10 31 25 8 74
BOYABAT

1999
HDD 439 354 287 128 38 140 315 403 2104
T≤15 °C 31 28 31 20 7 22 30 31 200
CDD 25 82 79 3 4 193
T>22 °C 14 25 21 4 3 67
BOYABAT

1998
HDD 470 402 343 59 11 64 260 414 2023
T≤15 °C 31 28 31 11 3 13 30 31 178
CDD 5 1 28 100 91 20 245
T>22 °C 2 2 14 27 27 9 81
BOYABAT

1997
HDD 458 427 400 241 26 6 27 117 302 439 2443
T≤15 °C 31 28 31 27 6 1 7 20 30 31 212
CDD 10 19 71 38 138
T>22 °C 10 12 24 19 65
BOYABAT

1996
HDD 446 345 370 182 9 122 317 362 2153
T≤15 °C 31 29 31 24 2 18 30 31 196
CDD 7 27 102 54 3 193
T>22 °C 6 13 24 21 2 66
BOYABAT

1995
HDD 410 348 245 156 50 3 135 345 457 2149
T≤15 °C 31 28 30 21 10 1 28 30 31 210
CDD 21 54 41 67 14 197
T>22 °C 11 19 23 26 8 87
BOYABAT

1994
HDD 433 389 312 74 42 48 322 494 2114
T≤15 °C 31 28 30 14 11 10 30 31 185
CDD 13 23 77 51 51 0 215
T>22 °C 8 16 30 27 24 2 107
BOYABAT

1993
HDD 613 439 319 171 27 4 43 379 413 2408
T≤15 °C 31 28 30 26 7 1 7 30 31 191
CDD 0 16 46 36 9 107
T>22 °C 1 8 17 23 9 58
BOYABAT

1992
HDD 556 479 334 167 37 21 49 333 513 2489
T≤15 °C 31 29 30 26 8 5 9 30 31 199
CDD 7 23 53 17 100
T>22 °C 5 13 28 6 52

Kontrolden geçmemiş verilerle hazırlanmıştır.

  1. G/D = Gün-Derece
  2. HDD = Isıtma Gün-Derecesi
  3. CDD = Soğutma Gün-Derecesi
  4. T≤15°C = Sıcaklığın ≤15°C olduğu gun sayısı
  5. T>22°C = Sıcaklığın >22°C olduğu gun sayısı

Gün derece, 24 saatlik periyodun ne kadarının sıcak ve ne kadarının soğuk geçtiğini ölçmeye yarayan bir birimdir.

Isıtma Gün Dereceleri [Heating Degree Days – HDD]

Belirli bir zamanda (gün, ay, yıl) dış ortam ve oda sıcaklığını hesaba katarak soğuğun şiddetini açıklar. Birçok ülke gün derecenin hesabı için farklı tanımlar kullanır. Karşılaştırılabilir ve ortak bir kullanım oluşturmak için Avrupa Topluluğu İstatistik Ofisi (Eurostat) HDD’nin hesabı için aşağıdaki metodu önermektedir.

HDD = (18 °C - Tm) x değer Tm ≤ 15 °C (ısıtma eşiği)
HDD = 0 eğer Tm > 15 °C

Burada; Tm = Günlük ortalama sıcaklık, d= Gün sayısıdır.

Hesaplama günlük bazda yapılır. Aylık ve yıllık gün dereceler bunların toplanması ile bulunur.

ÖRNEK:
Ankara’nın 29 Aralık 2005 günü ortalama sıcaklığı 2.0°C’ dir. Buna göre:
HDD = 18-2=16 dır.

Göreceli ısıtma gün dereceleri ise güncel gün derece ile uzun dönem ortalama gün derece arasındaki orandır. Güncel gün derece / Uzun dönem ortalama gün derece

Soğutma Gün Dereceleri [Cooling Degree Days – CDD]

Belirli bir zamanda (gün, ay, yıl) dış ortam sıcaklığını hesaba katarak sıcaklığın şiddetini açıklar. Resmi olarak belirlenmiş bir eşik sıcaklık olmamakla birlikte inşaat sektörü enerji yönetim pratiklerinde eşik sıcaklık 22°C olarak alınır. Buna göre:

CDD = (Tm - 22) x değer Tm > 22 °C (soğutma eşiği)
CDD = 0 eğer eğer Tm ≤ 22°C

ÖRNEK:Ankara’nın 25 Ağustos 2005 günü ortalama sıcaklığı 25.9°C’ dir. Buna göre:
CDD = 25.9-22 = 3.9 dır.

Gün Derece toplamına neden ihtiyaç vardır?

  1. Isıtma yada soğutma gün dereceleri toplamının bilinmesi binaların ısıtılması yada soğutulması için gerekli olan enerji gereksiniminin bilinmesi açısından önemlidir. Dış ortam sıcaklığı 15°C’nin üzerinde ise ısıtma gereksizdir. Isıtma maliyeti yıllık HDD ile doğrudan orantılıdır. Bunun için 1 yıl içindeki yakıt maliyeti Yıllık HDD’ye bölünerek 1 HDD için ısıtma fiyatı çıkartılır. Daha sonraki hesaplamalar için bu indis kullanılır.
  2. HDD kış mevsiminin sertliğini göreceli olarak önceki ve uzun yıllara göre karşılaştırmak için de kullanılır.
  3. HDD aynı zamanda yeni binalar yapılırken yalıtım, ısıtma ve soğutma giderlerinin hesaplanması için inşaat sektörü tarafından ihtiyaç duyulan bir parametredir.