Isıtma ve Soğutma Gün Dereceleri

Gösterim Şekli Aylık Değerlendirme Yıllık Değerlendirme


Merkez G/D Oca Şub Mar Nis May Haz Tem Ağu Eyl Eki Kas Ara Yıllık
KALE-DEMRE

2024
HDD 70 57 13 140
T≤15 °C 14 13 4 31
CDD 1 18 51 255 325 311 961
T>22 °C 1 12 21 30 31 31 126
KALE-DEMRE

2023
HDD 115 149 16 3 9 18 310
T≤15 °C 24 24 4 1 2 5 60
CDD 25 138 305 309 206 57 6 1046
T>22 °C 16 30 31 31 30 31 8 177
KALE-DEMRE

2022
HDD 187 102 144 28 461
T≤15 °C 27 19 25 7 78
CDD 4 60 166 277 285 181 54 1027
T>22 °C 3 21 30 31 31 30 20 166
KALE-DEMRE

2021
HDD 181 145 157 48 103 634
T≤15 °C 28 23 27 9 19 106
CDD 6 130 304 324 173 48 985
T>22 °C 8 28 31 31 30 22 150
KALE-DEMRE

2020
HDD 234 185 124 34 47 146 770
T≤15 °C 31 29 24 9 12 28 133
CDD 36 60 226 231 174 18 745
T>22 °C 8 22 31 31 30 15 137
KALE-DEMRE

2019
HDD 222 163 145 61 11 166 768
T≤15 °C 29 25 29 15 3 29 130
CDD 27 110 193 231 117 17 695
T>22 °C 12 28 31 31 30 15 147
KALE-DEMRE

2018
HDD 213 136 66 7 32 178 632
T≤15 °C 31 26 17 2 9 28 113
CDD 1 43 108 218 227 132 9 738
T>22 °C 1 21 30 31 31 30 11 155
KALE-DEMRE

2017
HDD 263 182 131 15 60 156 807
T≤15 °C 31 26 26 4 12 27 126
CDD 6 108 248 226 125 2 715
T>22 °C 4 30 31 31 30 5 131
KALE-DEMRE

2016
HDD 239 109 86 48 254 736
T≤15 °C 31 21 19 12 31 114
CDD 2 132 240 242 118 15 749
T>22 °C 6 29 31 31 28 14 139
KALE-DEMRE

2015
HDD 223 182 110 47 15 205 782
T≤15 °C 30 24 24 12 4 31 125
CDD 12 71 208 250 147 25 713
T>22 °C 8 30 31 31 30 20 150
KALE-DEMRE

2014
HDD 191 167 128 11 41 112 650
T≤15 °C 31 28 28 3 8 22 120
CDD 7 95 207 241 122 3 675
T>22 °C 7 25 31 31 29 6 129
KALE-DEMRE

2013
HDD 207 139 105 37 199 687
T≤15 °C 29 25 20 9 27 110
CDD 2 32 102 197 234 105 2 674
T>22 °C 1 22 30 31 31 30 4 149
KALE-DEMRE

2012
HDD 238 212 153 11 17 171 802
T≤15 °C 30 29 27 3 5 27 121
CDD 3 140 262 256 126 28 815
T>22 °C 5 28 31 31 30 15 140
KALE-DEMRE

2011
HDD 197 160 131 14 107 193 802
T≤15 °C 31 27 26 4 19 28 135
CDD 10 117 235 247 142 6 757
T>22 °C 6 30 31 31 30 7 135
KALE-DEMRE

2010
HDD 169 126 65 10 98 468
T≤15 °C 27 23 15 3 20 88
CDD 19 109 222 280 151 19 4 804
T>22 °C 12 30 31 31 30 12 2 148
KALE-DEMRE

2009
HDD 176 173 134 49 126 658
T≤15 °C 28 26 24 14 25 117
CDD 14 131 228 226 100 24 723
T>22 °C 10 30 31 31 30 19 151
KALE-DEMRE

2008
HDD 251 231 89 23 15 165 774
T≤15 °C 31 29 20 6 4 26 116
CDD 14 137 233 259 128 4 775
T>22 °C 9 30 31 31 29 4 134
KALE-DEMRE

2007
HDD 239 187 137 37 76 176 852
T≤15 °C 31 28 28 9 17 27 140
CDD 13 135 237 236 114 28 763
T>22 °C 11 27 31 31 28 14 142
KALE-DEMRE

2006
HDD 250 199 149 18 104 227 947
T≤15 °C 30 28 27 5 22 31 143
CDD 22 103 201 223 112 12 673
T>22 °C 10 28 31 31 27 11 138
KALE-DEMRE

2005
HDD 231 218 155 50 6 122 203 985
T≤15 °C 28 27 27 10 1 23 30 146
CDD 3 71 194 204 78 0 550
T>22 °C 4 27 31 31 30 1 124
KALE-DEMRE

2004
HDD 247 209 137 36 85 208 922
T≤15 °C 31 27 24 9 12 30 133
CDD 2 88 191 200 104 14 599
T>22 °C 3 26 31 31 30 8 129
KALE-DEMRE

2003
HDD 162 226 204 41 6 80 171 890
T≤15 °C 28 26 31 10 2 20 27 144
CDD 26 108 184 183 70 18 589
T>22 °C 16 27 31 31 30 12 147
KALE-DEMRE

2002
HDD 269 146 107 30 51 180 783
T≤15 °C 31 24 22 7 13 28 125
CDD 0 99 195 167 83 2 546
T>22 °C 2 27 31 31 29 2 122
KALE-DEMRE

2001
HDD 202 197 56 41 72 202 770
T≤15 °C 30 27 15 12 13 30 127
CDD 2 22 87 195 218 94 7 625
T>22 °C 1 13 28 31 31 29 9 142
KALE-DEMRE

2000
HDD 289 231 201 17 63 199 1000
T≤15 °C 31 29 29 4 15 30 138
CDD 8 111 228 194 104 4 649
T>22 °C 8 30 31 31 28 4 132
KALE-DEMRE

1999
HDD 195 170 153 33 38 158 747
T≤15 °C 31 25 29 7 6 26 124
CDD 10 103 221 215 109 20 678
T>22 °C 10 30 31 31 30 9 141
KALE-DEMRE

1998
HDD 229 186 198 34 27 180 854
T≤15 °C 30 28 30 8 7 28 131
CDD 1 4 106 224 246 90 9 680
T>22 °C 1 5 30 31 31 27 9 134
KALE-DEMRE

1997
HDD 216 222 206 117 8 8 30 158 965
T≤15 °C 30 28 31 18 2 2 8 25 144
CDD 10 81 186 148 43 468
T>22 °C 14 21 31 31 25 122
KALE-DEMRE

1996
HDD 248 181 168 95 11 52 141 896
T≤15 °C 31 28 27 22 3 13 27 151
CDD 18 96 182 201 56 553
T>22 °C 12 30 31 31 25 129
KALE-DEMRE

1995
HDD 195 188 173 99 145 202 1002
T≤15 °C 30 28 30 18 23 31 160
CDD 5 101 172 190 87 1 556
T>22 °C 4 30 31 31 30 2 128
KALE-DEMRE

1994
HDD 191 210 169 23 97 234 924
T≤15 °C 29 28 31 6 17 31 142
CDD 1 27 63 176 192 124 28 611
T>22 °C 1 13 27 31 31 30 15 148
KALE-DEMRE

1993
HDD 299 266 220 77 4 77 184 1127
T≤15 °C 31 28 30 15 1 17 30 152
CDD 2 68 157 187 72 5 491
T>22 °C 2 28 31 31 29 5 126
KALE-DEMRE

1992
HDD 289 284 219 76 93 250 1211
T≤15 °C 31 29 30 19 18 31 158
CDD 0 53 162 181 66 2 464
T>22 °C 2 27 31 31 27 2 120

Kontrolden geçmemiş verilerle hazırlanmıştır.

  1. G/D = Gün-Derece
  2. HDD = Isıtma Gün-Derecesi
  3. CDD = Soğutma Gün-Derecesi
  4. T≤15°C = Sıcaklığın ≤15°C olduğu gun sayısı
  5. T>22°C = Sıcaklığın >22°C olduğu gun sayısı

Gün derece, 24 saatlik periyodun ne kadarının sıcak ve ne kadarının soğuk geçtiğini ölçmeye yarayan bir birimdir.

Isıtma Gün Dereceleri [Heating Degree Days – HDD]

Belirli bir zamanda (gün, ay, yıl) dış ortam ve oda sıcaklığını hesaba katarak soğuğun şiddetini açıklar. Birçok ülke gün derecenin hesabı için farklı tanımlar kullanır. Karşılaştırılabilir ve ortak bir kullanım oluşturmak için Avrupa Topluluğu İstatistik Ofisi (Eurostat) HDD’nin hesabı için aşağıdaki metodu önermektedir.

HDD = (18 °C - Tm) x değer Tm ≤ 15 °C (ısıtma eşiği)
HDD = 0 eğer Tm > 15 °C

Burada; Tm = Günlük ortalama sıcaklık, d= Gün sayısıdır.

Hesaplama günlük bazda yapılır. Aylık ve yıllık gün dereceler bunların toplanması ile bulunur.

ÖRNEK:
Ankara’nın 29 Aralık 2005 günü ortalama sıcaklığı 2.0°C’ dir. Buna göre:
HDD = 18-2=16 dır.

Göreceli ısıtma gün dereceleri ise güncel gün derece ile uzun dönem ortalama gün derece arasındaki orandır. Güncel gün derece / Uzun dönem ortalama gün derece

Soğutma Gün Dereceleri [Cooling Degree Days – CDD]

Belirli bir zamanda (gün, ay, yıl) dış ortam sıcaklığını hesaba katarak sıcaklığın şiddetini açıklar. Resmi olarak belirlenmiş bir eşik sıcaklık olmamakla birlikte inşaat sektörü enerji yönetim pratiklerinde eşik sıcaklık 22°C olarak alınır. Buna göre:

CDD = (Tm - 22) x değer Tm > 22 °C (soğutma eşiği)
CDD = 0 eğer eğer Tm ≤ 22°C

ÖRNEK:Ankara’nın 25 Ağustos 2005 günü ortalama sıcaklığı 25.9°C’ dir. Buna göre:
CDD = 25.9-22 = 3.9 dır.

Gün Derece toplamına neden ihtiyaç vardır?

  1. Isıtma yada soğutma gün dereceleri toplamının bilinmesi binaların ısıtılması yada soğutulması için gerekli olan enerji gereksiniminin bilinmesi açısından önemlidir. Dış ortam sıcaklığı 15°C’nin üzerinde ise ısıtma gereksizdir. Isıtma maliyeti yıllık HDD ile doğrudan orantılıdır. Bunun için 1 yıl içindeki yakıt maliyeti Yıllık HDD’ye bölünerek 1 HDD için ısıtma fiyatı çıkartılır. Daha sonraki hesaplamalar için bu indis kullanılır.
  2. HDD kış mevsiminin sertliğini göreceli olarak önceki ve uzun yıllara göre karşılaştırmak için de kullanılır.
  3. HDD aynı zamanda yeni binalar yapılırken yalıtım, ısıtma ve soğutma giderlerinin hesaplanması için inşaat sektörü tarafından ihtiyaç duyulan bir parametredir.