Isıtma ve Soğutma Gün Dereceleri

Gösterim Şekli Aylık Değerlendirme Yıllık Değerlendirme


Merkez G/D Oca Şub Mar Nis May Haz Tem Ağu Eyl Eki Kas Ara Yıllık
SİVRİCE

2024
HDD 492 399 374 1265
T≤15 °C 31 29 31 91
CDD 0
T>22 °C 0
SİVRİCE

2023
HDD 550 526 317 237 82 63 248 405 2428
T≤15 °C 31 28 31 30 15 15 27 31 208
CDD 11 87 150 30 278
T>22 °C 6 25 29 10 70
SİVRİCE

2022
HDD 599 422 505 135 127 4 99 282 416 2589
T≤15 °C 31 28 31 20 21 1 16 30 31 209
CDD 33 94 156 38 3 324
T>22 °C 17 28 31 13 2 91
SİVRİCE

2021
HDD 532 404 399 157 16 15 118 263 495 2399
T≤15 °C 31 28 31 20 3 3 20 30 31 197
CDD 5 38 132 109 14 298
T>22 °C 2 15 30 29 9 85
SİVRİCE

2020
HDD 540 508 336 221 84 10 314 467 2480
T≤15 °C 31 29 31 28 14 3 28 31 195
CDD 20 127 75 49 271
T>22 °C 12 30 28 23 93
SİVRİCE

2019
HDD 554 434 402 289 49 5 68 287 436 2524
T≤15 °C 31 28 31 30 10 1 12 30 31 204
CDD 5 43 80 115 5 1 249
T>22 °C 5 21 27 27 6 1 87
SİVRİCE

2018
HDD 477 371 257 131 70 3 79 314 456 2158
T≤15 °C 31 28 31 23 14 1 13 30 31 202
CDD 29 125 116 27 297
T>22 °C 11 31 31 10 83
SİVRİCE

2017
HDD 607 505 366 236 72 3 127 321 444 2681
T≤15 °C 31 28 31 28 14 1 23 30 31 217
CDD 29 139 149 46 363
T>22 °C 12 30 31 20 93
SİVRİCE

2016
HDD 608 408 337 133 60 3 26 95 355 602 2627
T≤15 °C 31 29 31 21 13 1 5 18 30 31 210
CDD 33 89 160 9 291
T>22 °C 11 27 31 8 77
SİVRİCE

2015
HDD 596 427 403 264 84 80 311 503 2668
T≤15 °C 31 28 31 28 15 16 30 31 210
CDD 11 118 132 43 304
T>22 °C 11 31 25 20 87
SİVRİCE

2014
HDD 478 408 318 161 36 4 14 132 357 408 2316
T≤15 °C 31 28 31 24 9 1 3 21 30 31 209
CDD 1 30 133 148 27 339
T>22 °C 1 14 31 30 13 89
SİVRİCE

2013
HDD 558 415 361 181 42 8 170 254 602 2591
T≤15 °C 31 28 30 26 9 2 24 28 31 209
CDD 25 74 68 10 177
T>22 °C 11 26 30 6 73
SİVRİCE

2012
HDD 566 607 519 173 37 91 261 477 2731
T≤15 °C 31 29 31 27 8 18 30 31 205
CDD 38 113 103 14 268
T>22 °C 17 24 30 13 84
SİVRİCE

2011
HDD 524 470 389 241 120 142 451 551 2888
T≤15 °C 31 28 31 28 22 21 30 31 222
CDD 5 114 90 5 0 214
T>22 °C 7 28 31 5 1 72
SİVRİCE

2010
HDD 479 385 292 202 41 80 235 424 2138
T≤15 °C 31 28 29 30 8 16 30 31 203
CDD 37 137 148 45 367
T>22 °C 22 31 31 21 105
SİVRİCE

2009
HDD 581 433 413 250 85 47 53 331 414 2607
T≤15 °C 31 28 31 30 16 8 10 30 31 215
CDD 16 65 43 7 131
T>22 °C 10 26 20 8 64
SİVRİCE

2008
HDD 700 618 307 150 117 6 24 129 297 591 2939
T≤15 °C 31 29 30 19 19 2 6 25 30 31 222
CDD 6 20 104 135 28 293
T>22 °C 3 8 28 31 15 85
SİVRİCE

2007
HDD 649 503 403 342 21 90 359 551 2918
T≤15 °C 31 28 31 30 5 15 30 31 201
CDD 3 20 94 115 31 263
T>22 °C 3 11 26 30 11 81
SİVRİCE

2006
HDD 595 457 343 141 42 3 106 371 555 2613
T≤15 °C 31 28 31 20 10 1 18 30 31 200
CDD 3 86 106 182 14 391
T>22 °C 1 27 27 31 8 94
SİVRİCE

2005
HDD 546 470 365 147 40 4 3 137 354 470 2536
T≤15 °C 31 28 31 23 6 1 1 20 30 31 202
CDD 1 23 170 165 18 0 377
T>22 °C 1 15 31 31 12 1 91
SİVRİCE

2004
HDD 580 526 350 226 77 38 330 579 2706
T≤15 °C 31 29 31 26 15 7 30 31 200
CDD 2 33 118 137 22 1 313
T>22 °C 2 18 30 31 13 1 95
SİVRİCE

2003
HDD 509 539 529 239 25 8 12 79 336 500 2776
T≤15 °C 31 28 31 29 5 2 3 9 30 31 199
CDD 18 77 128 21 1 245
T>22 °C 13 30 31 5 2 81
SİVRİCE

2002
HDD 702 433 361 269 97 8 93 282 651 2896
T≤15 °C 31 28 31 30 18 2 15 30 31 216
CDD 19 100 67 9 195
T>22 °C 10 29 28 9 76
SİVRİCE

2001
HDD 531 436 277 178 134 127 387 497 2567
T≤15 °C 31 28 31 27 21 16 30 31 215
CDD 27 125 126 11 289
T>22 °C 17 29 30 13 89
SİVRİCE

2000
HDD 608 565 460 175 54 8 147 307 528 2852
T≤15 °C 31 29 31 26 11 2 21 30 31 212
CDD 19 175 106 8 308
T>22 °C 10 31 23 6 70
SİVRİCE

1999
HDD 506 421 381 209 39 126 315 454 2451
T≤15 °C 31 28 31 26 9 20 30 31 206
CDD 25 123 143 15 306
T>22 °C 13 31 29 11 84
SİVRİCE

1998
HDD 600 496 422 194 88 3 63 207 426 2499
T≤15 °C 31 28 31 23 18 1 12 29 31 204
CDD 49 155 157 35 396
T>22 °C 20 28 31 15 94
SİVRİCE

1997
HDD 507 567 513 292 33 12 104 307 473 2808
T≤15 °C 31 28 31 25 5 3 18 30 31 202
CDD 6 32 65 92 6 201
T>22 °C 7 15 25 30 4 81
SİVRİCE

1996
HDD 536 456 406 271 11 4 4 142 299 392 2521
T≤15 °C 31 29 31 28 3 1 1 19 30 31 204
CDD 27 158 124 13 0 322
T>22 °C 10 31 29 6 1 77
SİVRİCE

1995
HDD 548 443 356 237 77 3 16 134 386 533 2733
T≤15 °C 31 28 31 29 11 1 4 23 30 31 219
CDD 7 30 76 121 39 273
T>22 °C 4 12 29 29 15 89
SİVRİCE

1994
HDD 481 486 371 116 86 4 69 374 630 2617
T≤15 °C 31 28 31 20 15 1 14 30 31 201
CDD 14 25 117 85 49 290
T>22 °C 11 14 29 28 21 103
SİVRİCE

1993
HDD 672 581 453 256 153 7 9 44 451 457 3083
T≤15 °C 31 28 31 27 24 2 2 5 30 31 211
CDD 13 91 74 20 198
T>22 °C 8 24 28 14 74
SİVRİCE

1992
HDD 749 662 529 242 123 4 41 70 398 658 3476
T≤15 °C 31 29 31 29 21 1 6 12 30 31 221
CDD 2 36 79 27 144
T>22 °C 3 21 29 8 61

Kontrolden geçmemiş verilerle hazırlanmıştır.

  1. G/D = Gün-Derece
  2. HDD = Isıtma Gün-Derecesi
  3. CDD = Soğutma Gün-Derecesi
  4. T≤15°C = Sıcaklığın ≤15°C olduğu gun sayısı
  5. T>22°C = Sıcaklığın >22°C olduğu gun sayısı

Gün derece, 24 saatlik periyodun ne kadarının sıcak ve ne kadarının soğuk geçtiğini ölçmeye yarayan bir birimdir.

Isıtma Gün Dereceleri [Heating Degree Days – HDD]

Belirli bir zamanda (gün, ay, yıl) dış ortam ve oda sıcaklığını hesaba katarak soğuğun şiddetini açıklar. Birçok ülke gün derecenin hesabı için farklı tanımlar kullanır. Karşılaştırılabilir ve ortak bir kullanım oluşturmak için Avrupa Topluluğu İstatistik Ofisi (Eurostat) HDD’nin hesabı için aşağıdaki metodu önermektedir.

HDD = (18 °C - Tm) x değer Tm ≤ 15 °C (ısıtma eşiği)
HDD = 0 eğer Tm > 15 °C

Burada; Tm = Günlük ortalama sıcaklık, d= Gün sayısıdır.

Hesaplama günlük bazda yapılır. Aylık ve yıllık gün dereceler bunların toplanması ile bulunur.

ÖRNEK:
Ankara’nın 29 Aralık 2005 günü ortalama sıcaklığı 2.0°C’ dir. Buna göre:
HDD = 18-2=16 dır.

Göreceli ısıtma gün dereceleri ise güncel gün derece ile uzun dönem ortalama gün derece arasındaki orandır. Güncel gün derece / Uzun dönem ortalama gün derece

Soğutma Gün Dereceleri [Cooling Degree Days – CDD]

Belirli bir zamanda (gün, ay, yıl) dış ortam sıcaklığını hesaba katarak sıcaklığın şiddetini açıklar. Resmi olarak belirlenmiş bir eşik sıcaklık olmamakla birlikte inşaat sektörü enerji yönetim pratiklerinde eşik sıcaklık 22°C olarak alınır. Buna göre:

CDD = (Tm - 22) x değer Tm > 22 °C (soğutma eşiği)
CDD = 0 eğer eğer Tm ≤ 22°C

ÖRNEK:Ankara’nın 25 Ağustos 2005 günü ortalama sıcaklığı 25.9°C’ dir. Buna göre:
CDD = 25.9-22 = 3.9 dır.

Gün Derece toplamına neden ihtiyaç vardır?

  1. Isıtma yada soğutma gün dereceleri toplamının bilinmesi binaların ısıtılması yada soğutulması için gerekli olan enerji gereksiniminin bilinmesi açısından önemlidir. Dış ortam sıcaklığı 15°C’nin üzerinde ise ısıtma gereksizdir. Isıtma maliyeti yıllık HDD ile doğrudan orantılıdır. Bunun için 1 yıl içindeki yakıt maliyeti Yıllık HDD’ye bölünerek 1 HDD için ısıtma fiyatı çıkartılır. Daha sonraki hesaplamalar için bu indis kullanılır.
  2. HDD kış mevsiminin sertliğini göreceli olarak önceki ve uzun yıllara göre karşılaştırmak için de kullanılır.
  3. HDD aynı zamanda yeni binalar yapılırken yalıtım, ısıtma ve soğutma giderlerinin hesaplanması için inşaat sektörü tarafından ihtiyaç duyulan bir parametredir.