Isıtma ve Soğutma Gün Dereceleri

Gösterim Şekli Aylık Değerlendirme Yıllık Değerlendirme


Merkez G/D Oca Şub Mar Nis May Haz Tem Ağu Eyl Eki Kas Ara Yıllık
ANAMUR

2024
HDD 90 74 30 194
T≤15 °C 16 18 8 42
CDD 12 24 198 267 251 752
T>22 °C 8 18 30 31 31 118
ANAMUR

2023
HDD 120 174 21 4 9 27 355
T≤15 °C 30 25 5 1 2 7 70
CDD 13 88 247 235 174 63 12 832
T>22 °C 12 30 31 31 30 30 12 176
ANAMUR

2022
HDD 200 122 183 3 35 543
T≤15 °C 24 25 29 1 10 89
CDD 1 20 110 220 223 143 45 762
T>22 °C 1 10 30 31 31 30 26 159
ANAMUR

2021
HDD 118 88 83 25 113 427
T≤15 °C 18 16 20 6 19 79
CDD 4 22 89 240 253 141 37 786
T>22 °C 3 20 30 31 31 30 20 165
ANAMUR

2020
HDD 185 158 53 7 45 448
T≤15 °C 31 25 12 2 12 82
CDD 46 73 203 229 200 87 0 838
T>22 °C 13 25 31 31 30 31 1 162
ANAMUR

2019
HDD 203 118 80 24 105 530
T≤15 °C 30 25 17 7 23 102
CDD 21 108 204 226 154 73 3 789
T>22 °C 13 29 31 31 30 26 5 165
ANAMUR

2018
HDD 152 67 7 9 100 335
T≤15 °C 30 18 2 3 20 73
CDD 4 71 128 215 228 162 52 860
T>22 °C 3 26 30 31 31 30 23 174
ANAMUR

2017
HDD 232 164 63 3 22 63 547
T≤15 °C 31 27 14 1 6 13 92
CDD 5 92 238 222 150 22 729
T>22 °C 6 30 31 31 30 19 147
ANAMUR

2016
HDD 222 77 42 22 213 576
T≤15 °C 30 16 11 7 31 95
CDD 5 129 225 228 130 40 757
T>22 °C 4 30 31 31 30 28 154
ANAMUR

2015
HDD 193 159 72 16 3 111 554
T≤15 °C 31 25 17 4 1 26 104
CDD 17 74 193 235 161 56 736
T>22 °C 10 30 31 31 30 21 153
ANAMUR

2014
HDD 137 116 50 3 23 66 395
T≤15 °C 31 22 12 1 5 16 87
CDD 1 10 84 187 219 136 23 660
T>22 °C 1 9 27 31 31 30 17 146
ANAMUR

2013
HDD 191 119 80 6 3 174 573
T≤15 °C 31 24 17 2 1 28 103
CDD 5 17 95 198 248 114 8 0 685
T>22 °C 3 17 28 31 31 30 5 1 146
ANAMUR

2012
HDD 236 215 152 24 129 756
T≤15 °C 31 29 26 6 24 116
CDD 0 101 226 241 138 46 1 753
T>22 °C 2 27 31 31 30 19 3 143
ANAMUR

2011
HDD 169 148 67 7 64 160 615
T≤15 °C 31 27 12 2 16 30 118
CDD 10 88 191 215 136 13 653
T>22 °C 7 30 31 31 30 12 141
ANAMUR

2010
HDD 148 120 41 43 352
T≤15 °C 25 20 11 8 64
CDD 12 85 187 248 164 30 2 728
T>22 °C 13 30 31 31 30 17 2 154
ANAMUR

2009
HDD 167 141 121 4 4 84 521
T≤15 °C 30 23 26 1 1 21 102
CDD 5 122 208 204 111 51 701
T>22 °C 7 30 31 31 29 25 153
ANAMUR

2008
HDD 236 170 39 7 125 577
T≤15 °C 31 28 11 2 21 93
CDD 1 19 133 223 258 147 41 2 824
T>22 °C 2 12 30 31 31 30 25 3 164
ANAMUR

2007
HDD 169 104 72 20 7 124 496
T≤15 °C 31 19 17 5 2 24 98
CDD 16 120 240 269 151 48 1 845
T>22 °C 11 28 31 31 30 21 2 154
ANAMUR

2006
HDD 182 157 90 3 18 143 593
T≤15 °C 30 26 19 1 4 29 109
CDD 27 101 224 231 153 37 773
T>22 °C 12 29 31 31 30 18 151
ANAMUR

2005
HDD 197 190 92 30 4 54 88 655
T≤15 °C 31 25 20 6 1 12 13 108
CDD 3 66 210 226 109 15 629
T>22 °C 5 28 31 31 30 14 139
ANAMUR

2004
HDD 233 194 78 9 57 159 730
T≤15 °C 31 28 16 2 9 27 113
CDD 0 4 84 185 193 117 51 2 636
T>22 °C 1 5 27 31 31 30 27 2 154
ANAMUR

2003
HDD 132 215 174 14 8 24 143 710
T≤15 °C 27 27 30 4 2 6 24 120
CDD 28 105 209 216 118 31 707
T>22 °C 18 27 31 31 30 23 160
ANAMUR

2002
HDD 233 106 68 15 189 611
T≤15 °C 31 25 15 4 25 100
CDD 3 101 207 200 113 22 646
T>22 °C 5 29 31 31 30 15 141
ANAMUR

2001
HDD 154 158 7 7 3 61 148 538
T≤15 °C 30 26 2 2 1 11 28 100
CDD 2 24 80 185 205 110 31 637
T>22 °C 1 15 30 31 31 30 20 158
ANAMUR

2000
HDD 270 202 167 27 6 114 786
T≤15 °C 31 29 29 6 2 23 120
CDD 3 104 197 201 123 33 661
T>22 °C 4 30 31 31 30 14 140
ANAMUR

1999
HDD 162 160 104 26 28 89 569
T≤15 °C 29 28 23 6 5 23 114
CDD 14 98 206 229 127 46 720
T>22 °C 14 30 31 31 30 21 157
ANAMUR

1998
HDD 197 164 151 23 3 129 667
T≤15 °C 31 28 27 5 1 24 116
CDD 4 8 95 199 235 128 35 704
T>22 °C 3 8 30 31 31 30 16 149
ANAMUR

1997
HDD 149 197 166 99 10 141 762
T≤15 °C 28 26 28 16 3 25 126
CDD 1 11 91 201 149 68 19 540
T>22 °C 1 8 25 31 31 27 12 135
ANAMUR

1996
HDD 241 166 161 61 6 11 73 719
T≤15 °C 31 28 27 15 2 3 17 123
CDD 14 84 191 184 85 10 568
T>22 °C 8 29 31 31 30 11 140
ANAMUR

1995
HDD 185 140 126 49 3 102 171 776
T≤15 °C 29 28 26 11 1 17 31 143
CDD 19 103 195 192 116 5 630
T>22 °C 10 28 31 31 30 7 137
ANAMUR

1994
HDD 164 179 101 85 212 741
T≤15 °C 30 26 21 16 31 124
CDD 2 24 91 171 198 158 69 2 715
T>22 °C 1 14 30 31 31 30 19 4 160
ANAMUR

1993
HDD 234 243 178 43 3 70 106 877
T≤15 °C 31 28 29 11 1 13 25 138
CDD 5 65 168 177 85 47 547
T>22 °C 3 29 31 31 30 26 150
ANAMUR

1992
HDD 269 286 182 33 70 241 1081
T≤15 °C 31 29 27 9 10 31 137
CDD 3 42 132 188 87 13 3 468
T>22 °C 2 26 31 31 25 8 4 127

Kontrolden geçmemiş verilerle hazırlanmıştır.

  1. G/D = Gün-Derece
  2. HDD = Isıtma Gün-Derecesi
  3. CDD = Soğutma Gün-Derecesi
  4. T≤15°C = Sıcaklığın ≤15°C olduğu gun sayısı
  5. T>22°C = Sıcaklığın >22°C olduğu gun sayısı

Gün derece, 24 saatlik periyodun ne kadarının sıcak ve ne kadarının soğuk geçtiğini ölçmeye yarayan bir birimdir.

Isıtma Gün Dereceleri [Heating Degree Days – HDD]

Belirli bir zamanda (gün, ay, yıl) dış ortam ve oda sıcaklığını hesaba katarak soğuğun şiddetini açıklar. Birçok ülke gün derecenin hesabı için farklı tanımlar kullanır. Karşılaştırılabilir ve ortak bir kullanım oluşturmak için Avrupa Topluluğu İstatistik Ofisi (Eurostat) HDD’nin hesabı için aşağıdaki metodu önermektedir.

HDD = (18 °C - Tm) x değer Tm ≤ 15 °C (ısıtma eşiği)
HDD = 0 eğer Tm > 15 °C

Burada; Tm = Günlük ortalama sıcaklık, d= Gün sayısıdır.

Hesaplama günlük bazda yapılır. Aylık ve yıllık gün dereceler bunların toplanması ile bulunur.

ÖRNEK:
Ankara’nın 29 Aralık 2005 günü ortalama sıcaklığı 2.0°C’ dir. Buna göre:
HDD = 18-2=16 dır.

Göreceli ısıtma gün dereceleri ise güncel gün derece ile uzun dönem ortalama gün derece arasındaki orandır. Güncel gün derece / Uzun dönem ortalama gün derece

Soğutma Gün Dereceleri [Cooling Degree Days – CDD]

Belirli bir zamanda (gün, ay, yıl) dış ortam sıcaklığını hesaba katarak sıcaklığın şiddetini açıklar. Resmi olarak belirlenmiş bir eşik sıcaklık olmamakla birlikte inşaat sektörü enerji yönetim pratiklerinde eşik sıcaklık 22°C olarak alınır. Buna göre:

CDD = (Tm - 22) x değer Tm > 22 °C (soğutma eşiği)
CDD = 0 eğer eğer Tm ≤ 22°C

ÖRNEK:Ankara’nın 25 Ağustos 2005 günü ortalama sıcaklığı 25.9°C’ dir. Buna göre:
CDD = 25.9-22 = 3.9 dır.

Gün Derece toplamına neden ihtiyaç vardır?

  1. Isıtma yada soğutma gün dereceleri toplamının bilinmesi binaların ısıtılması yada soğutulması için gerekli olan enerji gereksiniminin bilinmesi açısından önemlidir. Dış ortam sıcaklığı 15°C’nin üzerinde ise ısıtma gereksizdir. Isıtma maliyeti yıllık HDD ile doğrudan orantılıdır. Bunun için 1 yıl içindeki yakıt maliyeti Yıllık HDD’ye bölünerek 1 HDD için ısıtma fiyatı çıkartılır. Daha sonraki hesaplamalar için bu indis kullanılır.
  2. HDD kış mevsiminin sertliğini göreceli olarak önceki ve uzun yıllara göre karşılaştırmak için de kullanılır.
  3. HDD aynı zamanda yeni binalar yapılırken yalıtım, ısıtma ve soğutma giderlerinin hesaplanması için inşaat sektörü tarafından ihtiyaç duyulan bir parametredir.