Isıtma ve Soğutma Gün Dereceleri

Gösterim Şekli Aylık Değerlendirme Yıllık Değerlendirme


Merkez G/D Oca Şub Mar Nis May Haz Tem Ağu Eyl Eki Kas Ara Yıllık
MUĞLA

2024
HDD 345 288 238 24 9 904
T≤15 °C 31 29 28 5 2 95
CDD 7 207 221 192 627
T>22 °C 5 29 31 31 96
MUĞLA

2023
HDD 350 359 254 195 31 7 164 278 1638
T≤15 °C 31 27 31 30 8 2 24 31 184
CDD 30 204 165 65 464
T>22 °C 13 31 31 25 100
MUĞLA

2022
HDD 438 333 409 86 16 24 190 282 1778
T≤15 °C 31 28 31 15 4 6 27 31 173
CDD 15 45 187 130 48 3 428
T>22 °C 8 20 31 29 20 2 110
MUĞLA

2021
HDD 351 278 317 134 66 158 349 1653
T≤15 °C 31 28 31 18 15 24 31 178
CDD 14 56 189 209 26 494
T>22 °C 5 14 31 31 15 96
MUĞLA

2020
HDD 393 318 249 113 25 4 21 209 294 1626
T≤15 °C 31 29 30 22 5 1 5 28 31 182
CDD 39 31 194 166 92 7 529
T>22 °C 8 12 31 31 25 3 110
MUĞLA

2019
HDD 405 310 248 168 33 17 181 336 1698
T≤15 °C 31 28 31 23 7 4 29 31 184
CDD 7 60 131 179 36 413
T>22 °C 6 19 29 31 15 100
MUĞLA

2018
HDD 381 266 221 45 51 186 369 1519
T≤15 °C 31 28 31 10 8 28 31 167
CDD 13 28 147 146 67 401
T>22 °C 9 15 31 31 22 108
MUĞLA

2017
HDD 450 319 253 147 11 55 263 313 1811
T≤15 °C 31 28 30 25 3 11 30 31 189
CDD 2 71 205 127 56 461
T>22 °C 3 20 31 31 19 104
MUĞLA

2016
HDD 422 247 259 47 38 18 240 440 1711
T≤15 °C 31 29 31 10 8 4 28 31 172
CDD 96 187 174 36 493
T>22 °C 19 31 31 16 97
MUĞLA

2015
HDD 398 338 286 193 19 33 180 375 1822
T≤15 °C 31 28 31 27 5 7 29 31 189
CDD 5 13 157 163 74 412
T>22 °C 4 7 29 31 19 90
MUĞLA

2014
HDD 340 275 260 149 39 5 58 220 275 1621
T≤15 °C 31 28 31 25 9 1 13 29 31 198
CDD 0 47 124 164 15 350
T>22 °C 1 14 31 31 12 89
MUĞLA

2013
HDD 385 304 257 121 8 98 204 406 1783
T≤15 °C 31 28 31 21 2 18 30 31 192
CDD 2 11 72 151 184 31 451
T>22 °C 1 8 17 30 31 13 100
MUĞLA

2012
HDD 445 386 299 119 27 29 151 336 1792
T≤15 °C 31 29 31 21 6 7 24 31 180
CDD 116 229 162 63 6 576
T>22 °C 23 31 31 20 4 109
MUĞLA

2011
HDD 391 307 294 188 38 106 288 367 1979
T≤15 °C 31 28 31 29 9 19 30 31 208
CDD 48 176 171 74 469
T>22 °C 13 31 31 21 96
MUĞLA

2010
HDD 345 277 233 107 23 60 128 290 1463
T≤15 °C 31 28 31 18 5 12 24 31 180
CDD 7 38 144 221 46 456
T>22 °C 5 9 31 31 19 95
MUĞLA

2009
HDD 356 347 309 126 40 29 229 290 1726
T≤15 °C 31 28 29 23 8 7 30 31 187
CDD 0 71 161 141 23 396
T>22 °C 1 24 31 31 8 95
MUĞLA

2008
HDD 431 371 233 147 26 7 43 182 341 1781
T≤15 °C 31 29 29 20 6 2 11 28 31 187
CDD 12 101 174 201 57 545
T>22 °C 5 21 31 31 17 105
MUĞLA

2007
HDD 385 322 262 148 5 53 241 398 1814
T≤15 °C 31 28 31 26 1 12 27 31 187
CDD 2 113 210 175 34 2 536
T>22 °C 1 21 31 30 14 3 100
MUĞLA

2006
HDD 414 344 295 90 51 3 47 262 354 1860
T≤15 °C 31 28 31 20 11 1 10 30 31 193
CDD 22 63 134 176 39 434
T>22 °C 8 18 29 31 17 103
MUĞLA

2005
HDD 356 369 273 145 21 95 267 346 1872
T≤15 °C 31 28 31 19 5 16 30 31 191
CDD 1 35 155 136 25 352
T>22 °C 2 15 29 30 13 89
MUĞLA

2004
HDD 428 347 249 145 19 17 218 336 1759
T≤15 °C 31 29 30 24 5 4 25 31 179
CDD 57 158 102 38 355
T>22 °C 20 31 29 17 97
MUĞLA

2003
HDD 297 415 335 181 5 44 202 341 1820
T≤15 °C 31 28 31 27 1 7 26 31 182
CDD 20 74 149 171 24 438
T>22 °C 12 24 31 31 8 106
MUĞLA

2002
HDD 421 261 236 162 30 209 379 1698
T≤15 °C 31 28 30 25 7 30 31 182
CDD 70 128 109 307
T>22 °C 23 29 28 80
MUĞLA

2001
HDD 333 324 141 159 37 37 231 378 1640
T≤15 °C 31 28 23 24 8 6 27 31 178
CDD 8 74 183 159 41 4 469
T>22 °C 7 23 31 31 13 3 108
MUĞLA

2000
HDD 484 377 342 124 16 69 168 334 1914
T≤15 °C 31 29 31 22 4 12 27 31 187
CDD 1 91 183 146 35 0 456
T>22 °C 2 22 31 31 15 1 102
MUĞLA

1999
HDD 339 338 276 132 7 192 296 1580
T≤15 °C 31 28 31 21 2 27 31 171
CDD 3 55 163 153 15 389
T>22 °C 4 27 31 31 13 106
MUĞLA

1998
HDD 391 290 370 131 36 41 194 350 1803
T≤15 °C 31 28 31 21 9 8 29 31 188
CDD 57 182 217 40 6 502
T>22 °C 22 31 31 15 3 102
MUĞLA

1997
HDD 346 358 348 289 28 86 212 345 2012
T≤15 °C 31 28 31 27 4 14 30 31 196
CDD 10 74 126 58 15 283
T>22 °C 7 15 31 23 13 89
MUĞLA

1996
HDD 414 324 350 226 13 4 113 201 291 1936
T≤15 °C 31 29 31 28 3 1 19 29 31 202
CDD 16 80 168 134 8 406
T>22 °C 10 24 31 31 6 102
MUĞLA

1995
HDD 375 295 300 194 47 80 332 323 1946
T≤15 °C 31 28 31 25 8 14 30 31 198
CDD 11 75 123 110 17 336
T>22 °C 7 28 29 28 11 103
MUĞLA

1994
HDD 341 341 283 119 67 20 260 410 1841
T≤15 °C 31 28 31 20 12 6 27 31 186
CDD 26 56 128 157 85 6 458
T>22 °C 10 18 31 30 28 5 122
MUĞLA

1993
HDD 416 400 325 154 77 10 241 318 1941
T≤15 °C 31 28 31 21 16 3 28 31 189
CDD 4 43 125 170 23 5 370
T>22 °C 2 17 30 31 14 2 96
MUĞLA

1992
HDD 468 451 364 176 32 18 229 439 2177
T≤15 °C 31 29 31 26 7 4 25 31 184
CDD 26 79 135 32 3 275
T>22 °C 16 27 29 14 2 88

Kontrolden geçmemiş verilerle hazırlanmıştır.

  1. G/D = Gün-Derece
  2. HDD = Isıtma Gün-Derecesi
  3. CDD = Soğutma Gün-Derecesi
  4. T≤15°C = Sıcaklığın ≤15°C olduğu gun sayısı
  5. T>22°C = Sıcaklığın >22°C olduğu gun sayısı

Gün derece, 24 saatlik periyodun ne kadarının sıcak ve ne kadarının soğuk geçtiğini ölçmeye yarayan bir birimdir.

Isıtma Gün Dereceleri [Heating Degree Days – HDD]

Belirli bir zamanda (gün, ay, yıl) dış ortam ve oda sıcaklığını hesaba katarak soğuğun şiddetini açıklar. Birçok ülke gün derecenin hesabı için farklı tanımlar kullanır. Karşılaştırılabilir ve ortak bir kullanım oluşturmak için Avrupa Topluluğu İstatistik Ofisi (Eurostat) HDD’nin hesabı için aşağıdaki metodu önermektedir.

HDD = (18 °C - Tm) x değer Tm ≤ 15 °C (ısıtma eşiği)
HDD = 0 eğer Tm > 15 °C

Burada; Tm = Günlük ortalama sıcaklık, d= Gün sayısıdır.

Hesaplama günlük bazda yapılır. Aylık ve yıllık gün dereceler bunların toplanması ile bulunur.

ÖRNEK:
Ankara’nın 29 Aralık 2005 günü ortalama sıcaklığı 2.0°C’ dir. Buna göre:
HDD = 18-2=16 dır.

Göreceli ısıtma gün dereceleri ise güncel gün derece ile uzun dönem ortalama gün derece arasındaki orandır. Güncel gün derece / Uzun dönem ortalama gün derece

Soğutma Gün Dereceleri [Cooling Degree Days – CDD]

Belirli bir zamanda (gün, ay, yıl) dış ortam sıcaklığını hesaba katarak sıcaklığın şiddetini açıklar. Resmi olarak belirlenmiş bir eşik sıcaklık olmamakla birlikte inşaat sektörü enerji yönetim pratiklerinde eşik sıcaklık 22°C olarak alınır. Buna göre:

CDD = (Tm - 22) x değer Tm > 22 °C (soğutma eşiği)
CDD = 0 eğer eğer Tm ≤ 22°C

ÖRNEK:Ankara’nın 25 Ağustos 2005 günü ortalama sıcaklığı 25.9°C’ dir. Buna göre:
CDD = 25.9-22 = 3.9 dır.

Gün Derece toplamına neden ihtiyaç vardır?

  1. Isıtma yada soğutma gün dereceleri toplamının bilinmesi binaların ısıtılması yada soğutulması için gerekli olan enerji gereksiniminin bilinmesi açısından önemlidir. Dış ortam sıcaklığı 15°C’nin üzerinde ise ısıtma gereksizdir. Isıtma maliyeti yıllık HDD ile doğrudan orantılıdır. Bunun için 1 yıl içindeki yakıt maliyeti Yıllık HDD’ye bölünerek 1 HDD için ısıtma fiyatı çıkartılır. Daha sonraki hesaplamalar için bu indis kullanılır.
  2. HDD kış mevsiminin sertliğini göreceli olarak önceki ve uzun yıllara göre karşılaştırmak için de kullanılır.
  3. HDD aynı zamanda yeni binalar yapılırken yalıtım, ısıtma ve soğutma giderlerinin hesaplanması için inşaat sektörü tarafından ihtiyaç duyulan bir parametredir.