Isıtma ve Soğutma Gün Dereceleri

Gösterim Şekli Aylık Değerlendirme Yıllık Değerlendirme


Merkez G/D Oca Şub Mar Nis May Haz Tem Ağu Eyl Eki Kas Ara Yıllık
SAKARYA

2024
HDD 294 204 209 32 37 776
T≤15 °C 30 25 26 9 9 99
CDD 6 1 104 151 116 378
T>22 °C 4 1 30 31 31 97
SAKARYA

2023
HDD 250 290 230 117 43 6 102 197 1235
T≤15 °C 28 25 29 20 10 2 17 26 157
CDD 16 102 122 21 1 3 265
T>22 °C 10 30 31 11 1 1 84
SAKARYA

2022
HDD 367 257 373 109 58 7 35 113 200 1519
T≤15 °C 30 28 29 17 13 2 7 18 25 169
CDD 2 17 24 56 109 32 4 1 245
T>22 °C 1 6 23 29 31 12 2 1 105
SAKARYA

2021
HDD 238 273 314 151 17 7 4 46 142 208 1400
T≤15 °C 24 23 31 20 4 2 1 9 21 23 158
CDD 8 25 102 96 13 244
T>22 °C 4 9 29 31 6 79
SAKARYA

2020
HDD 364 256 216 166 44 141 143 1330
T≤15 °C 31 26 25 22 11 26 22 163
CDD 17 53 118 126 87 24 425
T>22 °C 6 24 31 31 28 10 130
SAKARYA

2019
HDD 321 293 235 166 10 3 77 251 1356
T≤15 °C 31 28 27 23 2 1 16 28 156
CDD 23 52 55 64 10 2 0 206
T>22 °C 8 27 23 27 10 2 1 98
SAKARYA

2018
HDD 321 249 175 84 7 4 17 142 330 1329
T≤15 °C 31 25 25 18 2 1 3 22 31 158
CDD 2 9 43 91 115 20 280
T>22 °C 1 4 21 31 31 7 95
SAKARYA

2017
HDD 433 273 244 166 13 63 178 211 1581
T≤15 °C 31 25 30 22 4 14 26 24 176
CDD 3 39 84 86 37 249
T>22 °C 2 16 30 24 16 88
SAKARYA

2016
HDD 365 180 193 45 18 3 73 212 437 1526
T≤15 °C 28 22 24 9 5 1 14 24 31 158
CDD 2 13 68 82 108 27 3 303
T>22 °C 1 5 22 30 30 16 1 105
SAKARYA

2015
HDD 353 276 269 175 4 40 112 338 1567
T≤15 °C 30 24 29 22 1 8 19 31 164
CDD 5 8 70 106 50 0 239
T>22 °C 4 8 27 31 27 1 98
SAKARYA

2014
HDD 252 238 197 86 18 28 162 241 1222
T≤15 °C 30 27 28 17 4 6 23 31 166
CDD 9 32 90 104 21 256
T>22 °C 4 16 30 30 13 93
SAKARYA

2013
HDD 286 223 167 93 107 126 376 1378
T≤15 °C 28 25 19 15 20 21 31 159
CDD 2 4 25 37 70 94 6 238
T>22 °C 1 3 9 16 27 31 5 92
SAKARYA

2012
HDD 390 397 309 46 107 269 1518
T≤15 °C 31 29 31 6 21 28 146
CDD 0 1 73 158 109 30 16 0 387
T>22 °C 1 2 26 31 27 20 10 1 118
SAKARYA

2011
HDD 340 322 266 220 52 98 306 263 1867
T≤15 °C 31 28 26 30 9 17 30 29 200
CDD 21 130 54 16 221
T>22 °C 14 31 31 15 91
SAKARYA

2010
HDD 319 225 271 125 22 85 56 214 1317
T≤15 °C 25 25 31 21 6 17 11 23 159
CDD 18 38 115 174 11 5 5 366
T>22 °C 10 18 31 31 12 4 3 109
SAKARYA

2009
HDD 293 251 248 158 13 11 52 213 1239
T≤15 °C 29 26 26 26 3 3 10 26 149
CDD 11 70 154 64 7 0 306
T>22 °C 4 26 31 26 10 1 98
SAKARYA

2008
HDD 415 333 152 64 45 3 10 130 253 1405
T≤15 °C 31 28 23 11 10 1 3 21 26 154
CDD 9 11 50 76 118 26 1 291
T>22 °C 3 6 18 30 31 14 1 103
SAKARYA

2007
HDD 275 284 266 239 27 63 197 339 1690
T≤15 °C 28 28 29 30 5 13 26 31 190
CDD 1 3 67 86 82 16 255
T>22 °C 1 3 15 29 28 6 82
SAKARYA

2006
HDD 424 340 248 146 54 40 226 331 1809
T≤15 °C 31 28 29 24 10 9 27 31 189
CDD 14 44 48 124 4 234
T>22 °C 6 18 26 30 2 82
SAKARYA

2005
HDD 326 296 303 138 21 85 213 270 1652
T≤15 °C 30 26 29 16 4 12 26 29 172
CDD 1 1 4 74 95 9 184
T>22 °C 1 1 5 28 30 8 73
SAKARYA

2004
HDD 384 343 249 159 46 7 27 183 278 1676
T≤15 °C 30 27 25 22 10 2 7 20 31 174
CDD 1 1 14 40 44 21 3 124
T>22 °C 2 1 13 23 23 11 1 74
SAKARYA

2003
HDD 296 416 420 237 7 6 74 221 325 2002
T≤15 °C 30 28 31 27 2 2 12 26 31 189
CDD 0 35 73 85 9 15 217
T>22 °C 1 17 29 30 3 4 84
SAKARYA

2002
HDD 441 226 224 202 32 29 133 373 1660
T≤15 °C 31 27 26 25 9 6 20 31 175
CDD 2 31 114 38 6 0 191
T>22 °C 2 14 30 21 5 1 73
SAKARYA

2001
HDD 289 272 138 106 37 3 78 206 401 1530
T≤15 °C 30 25 20 16 8 1 13 25 31 169
CDD 4 4 19 111 86 14 0 238
T>22 °C 1 2 13 28 29 14 1 88
SAKARYA

2000
HDD 482 354 313 91 50 4 11 82 130 278 1795
T≤15 °C 31 29 27 16 10 1 3 13 21 27 178
CDD 2 1 18 88 57 16 182
T>22 °C 1 3 8 21 21 11 65
SAKARYA

1999
HDD 337 299 256 88 43 96 227 218 1564
T≤15 °C 31 27 28 15 8 20 28 28 185
CDD 1 3 26 80 75 4 0 189
T>22 °C 1 4 14 28 23 6 1 77
SAKARYA

1998
HDD 351 329 354 91 36 38 185 345 1729
T≤15 °C 30 28 30 15 9 8 26 29 175
CDD 15 5 25 65 78 11 199
T>22 °C 5 2 14 25 25 3 74
SAKARYA

1997
HDD 350 364 370 256 40 4 30 118 183 286 2001
T≤15 °C 31 28 30 27 7 1 7 19 26 29 205
CDD 15 30 54 13 3 115
T>22 °C 5 16 20 12 2 55
SAKARYA

1996
HDD 413 325 405 226 10 13 98 164 212 1866
T≤15 °C 31 26 31 26 3 3 16 25 26 187
CDD 3 10 54 39 5 111
T>22 °C 3 7 21 22 4 57
SAKARYA

1995
HDD 342 266 258 164 53 3 126 274 314 1800
T≤15 °C 30 26 29 21 10 1 27 25 27 196
CDD 13 21 27 40 12 113
T>22 °C 5 13 25 25 8 76
SAKARYA

1994
HDD 321 351 279 100 53 3 24 245 357 1733
T≤15 °C 31 28 28 19 12 1 6 24 31 180
CDD 3 21 16 43 57 37 8 185
T>22 °C 2 9 7 26 26 25 6 101
SAKARYA

1993
HDD 450 411 304 189 80 7 32 279 274 2026
T≤15 °C 31 28 25 25 14 2 6 25 30 186
CDD 1 7 26 21 31 6 92
T>22 °C 1 3 9 17 21 4 55
SAKARYA

1992
HDD 455 442 313 135 108 22 32 237 413 2157
T≤15 °C 31 29 27 19 22 5 7 26 31 197
CDD 18 8 59 12 6 103
T>22 °C 10 9 28 5 3 55

Kontrolden geçmemiş verilerle hazırlanmıştır.

  1. G/D = Gün-Derece
  2. HDD = Isıtma Gün-Derecesi
  3. CDD = Soğutma Gün-Derecesi
  4. T≤15°C = Sıcaklığın ≤15°C olduğu gun sayısı
  5. T>22°C = Sıcaklığın >22°C olduğu gun sayısı

Gün derece, 24 saatlik periyodun ne kadarının sıcak ve ne kadarının soğuk geçtiğini ölçmeye yarayan bir birimdir.

Isıtma Gün Dereceleri [Heating Degree Days – HDD]

Belirli bir zamanda (gün, ay, yıl) dış ortam ve oda sıcaklığını hesaba katarak soğuğun şiddetini açıklar. Birçok ülke gün derecenin hesabı için farklı tanımlar kullanır. Karşılaştırılabilir ve ortak bir kullanım oluşturmak için Avrupa Topluluğu İstatistik Ofisi (Eurostat) HDD’nin hesabı için aşağıdaki metodu önermektedir.

HDD = (18 °C - Tm) x değer Tm ≤ 15 °C (ısıtma eşiği)
HDD = 0 eğer Tm > 15 °C

Burada; Tm = Günlük ortalama sıcaklık, d= Gün sayısıdır.

Hesaplama günlük bazda yapılır. Aylık ve yıllık gün dereceler bunların toplanması ile bulunur.

ÖRNEK:
Ankara’nın 29 Aralık 2005 günü ortalama sıcaklığı 2.0°C’ dir. Buna göre:
HDD = 18-2=16 dır.

Göreceli ısıtma gün dereceleri ise güncel gün derece ile uzun dönem ortalama gün derece arasındaki orandır. Güncel gün derece / Uzun dönem ortalama gün derece

Soğutma Gün Dereceleri [Cooling Degree Days – CDD]

Belirli bir zamanda (gün, ay, yıl) dış ortam sıcaklığını hesaba katarak sıcaklığın şiddetini açıklar. Resmi olarak belirlenmiş bir eşik sıcaklık olmamakla birlikte inşaat sektörü enerji yönetim pratiklerinde eşik sıcaklık 22°C olarak alınır. Buna göre:

CDD = (Tm - 22) x değer Tm > 22 °C (soğutma eşiği)
CDD = 0 eğer eğer Tm ≤ 22°C

ÖRNEK:Ankara’nın 25 Ağustos 2005 günü ortalama sıcaklığı 25.9°C’ dir. Buna göre:
CDD = 25.9-22 = 3.9 dır.

Gün Derece toplamına neden ihtiyaç vardır?

  1. Isıtma yada soğutma gün dereceleri toplamının bilinmesi binaların ısıtılması yada soğutulması için gerekli olan enerji gereksiniminin bilinmesi açısından önemlidir. Dış ortam sıcaklığı 15°C’nin üzerinde ise ısıtma gereksizdir. Isıtma maliyeti yıllık HDD ile doğrudan orantılıdır. Bunun için 1 yıl içindeki yakıt maliyeti Yıllık HDD’ye bölünerek 1 HDD için ısıtma fiyatı çıkartılır. Daha sonraki hesaplamalar için bu indis kullanılır.
  2. HDD kış mevsiminin sertliğini göreceli olarak önceki ve uzun yıllara göre karşılaştırmak için de kullanılır.
  3. HDD aynı zamanda yeni binalar yapılırken yalıtım, ısıtma ve soğutma giderlerinin hesaplanması için inşaat sektörü tarafından ihtiyaç duyulan bir parametredir.